BPPVQ - GC-100: HARDENER COMPONENT

Product Identification

Product ID:GC-100: HARDENER COMPONENT
MSDS Date:05/08/1991
FSC:8030
NIIN:00N031086
Kit Part:Y
MSDS Number: BPPVQ

Responsible Party
AMERICAN SAFETY TECHNOLOGIES INC
565 EAGLE ROCK AVE
ROSELAND, NJ 07068
US

Emergency Phone: 201-403-2600;800-424-9300(CHEMTREC)

Info Phone: 201-403-2600

Preparer: F. LOELOFF

Cage: AMSAT

Contractor
AMERICAN SAFETY TECHNOLOGIES INC.
ROSELAND, NJ 07068 US

Telephone: 800-424-9300

Cage: AMSAT

Ingredients

MODIFIED CYCLOALIPHATIC POLYAMINE

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT)>2.37 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN: CAUSES IRRITATION AND
BURNS. INHAL: CAUSES NOSE AND THROAT IRRITATION. INGEST: WILL CAUSE
ESOPHAGEAL IRRITATION AND BURNS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:IRRITATION, SENSITIZATION AND DERMATITIS.
Medical Cond Aggravated by Exposure:ALLERGY, ECZEMA AND OTHER SKIN
CONDITIONS.

First Aid

First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING
AND WASH CONTACT AREA WITH MILD SOAP AND WATER. INHAL: REMOVE TO
FRESH AIR. I F BREATHING IS DIFFCULT, ADMINISTER O2.GET MEDICAL
ATTENTION. INGEST: IF CONSCIOUS, GIVE LARGE QTY OF MILK/WATER TO
DILUTE. DO NOT INDUCE VOMIT. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:CO2, CHEMICAL FOAM, DRY CHEMICAL OR WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL FIRE-EXPOSED CONTAINERS WITH WATER
SPRAY.
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.

Accidental Release

Spill Release Procedures:AVOID ALL PERSONAL CONTACT. DIKE SPILL. ABSORB
WITH INERT MATERIAL AND COLLECT FOR DISPOSAL. FLUSH CONTAMINATED
AREA WITH WATER; PREVENT WASHINGS FROM ENTERING WATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID ALL PERSONAL CONT. DO NOT EXCEED
110F/ 43C IN STORAGE AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC
VAPOR CARTRIDGE IF REQUIRED.
Ventilation:MECH VENT & LOC EXHAUST ARE RECOM. MECHANICAL EXHAUST IS
NOT RECOMMENDED AS SOLE MEANS OF CONTROLLING EMPLOYEE EXPOSURE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IN OPERATIONS WHERE CONTACT MAY OCCUR
COVERALLS, APRON & IMPERVIOUS FOOT COVERING ARE RECOM. SFTY SHOWER
& (SUPP DATA)
Work Hygienic Practices:IMMEDIATELY REMOVE AND THOROUGHLY LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
KEY1;C4.OTHER PROT EQUIP: EYE WASH FACILITY SHOULD BE AVAILABLE TO
EMPLOYEES.

Chemical Properties

HCC:C3
Spec Gravity:1.03
Evaporation Rate & Reference:<1(BUTYL ACETATE=1)
Solubility in Water:SOLUBLE
Appearance and Odor:YELLOW, CLEAR LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:CO, CO2 AND NOX.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.